If the septic tank has not been pumped in the last 12 months it will be necessary to have it pumped in order to obtain a municipal Certificate of On-site Systems Approval. Even if the tank has been pumped in the last 12 months, it may be necessary to pump the tank in order to safely run the SAT and/or ensure the property owner the maximum chance of passing the SAT.
The advantages of pumping the septic tank immediately prior to performing the SAT are summarized as follows:
- SO THE BASEMENT WON'T GET FLOODED!: During a SAT, a considerable amount of water is added to the drainfield. If it is overfilled, it may back-up into the septic tank. If the septic tank is empty, the water will merely collect in the tank. However, if the septic tank is full (not pumped), the back-up from the drainfield may result in flooding the residence. When there is a significant drop in elevation from the house to the septic tank and/or drainfield, it may be physically impossible to cause a back-up. In such cases, it may be feasible to avoid pumping the septic tank. In most situations, there will be a potential for backing-up water into the house; therefore, the engineer will require that the septic tank be pumped. Under no circumstances should the drainfield be pumped, simply because it will reduce the chances of the drainfield passing an adequacy test (see next section).
- PROPERTY OWNER CAN RESUME NORMAL WATER USAGE: After the drainfield is filled with the required amount of water, the field engineer may need to monitor (for up to 24 hours) the recovery of the drainfield. If the septic tank is empty, the property owner will be able to use water in the residence normally since wastewater will merely flow into the empty septic tank and not reach the drainfield. However, if the tank is full (not pumped), any water used in the residence will flow into the drainfield and adversely affect the results of the adequacy test. In short, if the tank is not pumped, the resident may need to severely restrict water usage for up to 24 hours.
- PROPERTY OWNER SAVES MONEY!: The engineer will usually want to inspect the drainfield before the septic tank is pumped so that the normal operating level can be observed. In some cases, the engineer can visually determine that a drainfield is failed (operating with an excessive amount of water in it) without having to run the adequacy test, saving the property owner money. If the tank and/or the drainfield are pumped prior to the engineer’s inspection, the liquid levels will be artificially low, leading the engineer to believe an adequacy test is justified. Consequently, he/she will proceed with the test on a system that is certain to fail to meet the necessary absorption requirements.
- PUMPING THE SEPTIC TANK PREMATURELY OR PUMPING LIQUID OUT OF THE DRAINFIELD CAN REDUCE THE CHANCE OF A SYSTEM PASSING THE ADEQUACY TEST: A drainfield fails progressively over its life of operation (see Failed Septic System?). This progressive failure causes the liquid level in the field to rise into the uncontaminated drainrock, where the liquid can be absorbed into surrounding soils. This rising liquid level also increases the pressure below the water line, increasing the absorption rate. This progressive failure occurs until the system becomes so full that it eventually backs-up into the residence or overflows onto the ground. When a drainfield is pumped, the liquid level is lowered to a level where the drainrock and soil interface is more contaminated and the absorption rate is less. In short, the level in the drainfield will have been lowered into the failed portion of the system. If the engineer is not aware of this condition, he/she will not introduce enough water into the drainfield to get it above the normal operating level, and into the cleaner portion of the system where water can be more easily absorbed. This same condition occurs when a septic tank is pumped in the week prior to an adequacy test. During the time the septic tank is re-filling (after being pumped), no water will reach the drainfield. This will allow for the liquid level in the drainfield to drop down into the failed region. In order to maximize the chance of passing an adequacy test, water should be added to a drainfield that is operating at its normal liquid level, so that it can be filled into the uncontaminated portion of the system.